| Bildiri Türü | Tebliğ/Bildiri |
| Bildiri Alt Türü | Tam Metin Olarak Yayınlanan Tebliğ (Uluslararası Kongre/Sempozyum) |
| Bildiri Niteliği | Web of Science Kapsamındaki Kongre/Sempozyum |
| DOI Numarası | 10.1109/SIU.2018.8404303 |
| Bildiri Dili | Türkçe |
| Kongre Adı | 26th Signal Processing and Communications Applications Conference (SIU) |
| Kongre Tarihi | 02-05-2018 / 05-05-2018 |
| Basıldığı Ülke | |
| Basıldığı Şehir |
| Özet |
| Majority of the electricity used in the industry is consumed by induction motors. Early detection of abnormal cases that occur at the electrical and mechanical parts of these motors is very important for the safe operation of industrial facilities and the decrease of economic losses. In this presented study, the detection of parallel, angular and mixed misalignment fault in inverted fed induction motors has been carried out via the harmonic analysis of the instantaneous power signal. Results obtained from experimental studies carried out under different speed and loads indicated that the detection of misalignment fault can be carried out successfully. The presented method can be used effectively without any additional cost since inverter fed motors have both voltage and current sensors. |
| Anahtar Kelimeler |
| Fault diagnosis | Harmonic analysis | Induction motors | Misalignment |