Design Performance and Calibration of the CMS Hadron Outer Calorimeter
Yazarlar (1)
Doç. Dr. Mustafa Numan BAKIRCI Tokat Gaziosmanpaşa Üniversitesi, Türkiye
Makale Türü Açık Erişim Özgün Makale (Diğer hakemli uluslarası dergilerde yayınlanan tam makale)
Dergi Adı European Physical Journal C
Dergi ISSN 1434-6044 Wos Dergi Scopus Dergi
Makale Dili İngilizce Basım Tarihi 01-2008
Cilt / Sayı / Sayfa 57 / 3 / 653–663 DOI 10.1140/epjc/s10052-008-0756-6
UAK Araştırma Alanları
Yüksek Enerji ve Parçacık Fiziği
Özet
The Outer Hadron Calorimeter (HCAL HO) of the CMS detector is designed to measure the energy that is not contained by the barrel (HCAL HB) and electromagnetic (ECAL EB) calorimeters. Due to space limitation the barrel calorimeters do not contain completely the hadronic shower and an outer calorimeter (HO) was designed, constructed and inserted in the muon system of CMS to measure the energy leakage. Testing and calibration of the HO was carried out in a 300 GeV/c test beam that improved the linearity and resolution. HO will provide a net improvement in missing ET measurements at LHC energies. Information from HO will also be used for the muon trigger in CMS.
Anahtar Kelimeler
BM Sürdürülebilir Kalkınma Amaçları
Atıf Sayıları
Scopus 15
Google Scholar 87
Design Performance and Calibration of the CMS Hadron Outer Calorimeter

Paylaş