Performance study of the CMS barrel resistive plate chambers with cosmicrays
Yazarlar (1)
Doç. Dr. Mustafa Numan BAKIRCI Tokat Gaziosmanpaşa Üniversitesi, Türkiye
Makale Türü Açık Erişim Özgün Makale (SSCI, AHCI, SCI, SCI-Exp dergilerinde yayınlanan tam makale)
Dergi Adı Journal of Instrumentation (Q4)
Dergi ISSN 1748-0221 Wos Dergi Scopus Dergi
Dergi Tarandığı Indeksler SCI
Makale Dili İngilizce Basım Tarihi 03-2010
Cilt / Sayı / Sayfa 5 / 3 / – DOI 10.1088/1748-0221/5/03/T03017
UAK Araştırma Alanları
Yüksek Enerji ve Parçacık Fiziği
Özet
In October and November 2008, the CMS collaboration conducted a programme of cosmic ray data taking, which has recorded about 270 million events. The Resistive Plate Chamber system, which is part of the CMS muon detection system, was successfully operated in the full barrel. More than 98% of the channels were operational during the exercise with typical detection efficiency of 90%. In this paper, the performance of the detector during these dedicated runs is reported.
Anahtar Kelimeler
Atıf Sayıları
Scopus 55
Google Scholar 53
Google Scholar 61
Performance study of the CMS barrel resistive plate chambers with cosmicrays