Alignment of the CMS muon system with cosmic ray and beam halo muons
Yazarlar (1)
Doç. Dr. Mustafa Numan BAKIRCI Tokat Gaziosmanpaşa Üniversitesi, Türkiye
Makale Türü Açık Erişim Özgün Makale (SSCI, AHCI, SCI, SCI-Exp dergilerinde yayınlanan tam makale)
Dergi Adı Journal of Instrumentation (Q4)
Dergi ISSN 1748-0221 Wos Dergi Scopus Dergi
Dergi Tarandığı Indeksler SCI
Makale Dili İngilizce Basım Tarihi 03-2010
Cilt / Sayı / Sayfa 5 / 3 / – DOI 10.1088/1748-0221/5/03/T03020
UAK Araştırma Alanları
Yüksek Enerji ve Parçacık Fiziği
Özet
The CMS muon system has been aligned using cosmic-ray muons collected in 2008 and beam-halo muons from the 2008 LHC circulating beam tests. After alignment, the resolution of the most sensitive coordinate is 80 microns for the relative positions of superlayers in the same barrel chamber and 270 microns for the relative positions of endcap chambers in the same ring structure. The resolution on the position of the central barrel chambers relative to the tracker is comprised between two extreme estimates, 200 and 700 microns, provided by two complementary studies. With minor modifications, the alignment procedures can be applied using muons from LHC collisions, leading to additional significant improvements. © 2010 IOP Publishing Ltd and SISSA.
Anahtar Kelimeler
BM Sürdürülebilir Kalkınma Amaçları
Atıf Sayıları
Scopus 53
Alignment of the CMS muon system with cosmic ray and beam halo muons

Paylaş