| Makale Türü | Özgün Makale (SSCI, AHCI, SCI, SCI-Exp dergilerinde yayınlanan tam makale) | ||
| Dergi Adı | JOURNAL OF CLINICAL ANESTHESIA (Q4) | ||
| Dergi ISSN | 0952-8180 Wos Dergi Scopus Dergi | ||
| Dergi Tarandığı Indeksler | SCI-Expanded | ||
| Makale Dili | İngilizce | Basım Tarihi | 11-2016 |
| Cilt / Sayı / Sayfa | 34 / 0 / 358–364 | DOI | 10.1016/j.jclinane.2016.05.015 |
| Makale Linki | http://linkinghub.elsevier.com/retrieve/pii/S0952818016302008 | ||
| Özet |
| Study ObjectiveTo determine the effects of the McGrath Series 5 video laryngoscope on intraocular pressure (IOP) during laryngoscopy.DesignProspective, randomized, double blind.SettingOperating room.PatientsEighty adult patients of American Society of Anesthesiologist physical status 1 scheduled for nonophthalmic elective surgery under general anesthesia.InterventionsThe endotracheal intubation was provided using McGrath series 5 video laryngoscope in MG group (n = 40) or Macintosh laryngoscope in M group (n = 40).MeasurementsThe IOP of the right and left eyes was measured before and after the laryngoscopic process.Main ResultsThe mean arterial blood pressure values just before laryngoscopy and intubation and after intubation were 77.38 ± 6.18 and 97.38 ± 12.77 in the McGrath video laryngoscope group and 75.85 ± 7.88 and 99.12 ± 14.30 in the Macintosh laryngoscope group, respectively … |
| Anahtar Kelimeler |
| Anesthesia | Intraocular pressure | Ocular hemodynamics | Tonometry | Ocular |
| Atıf Sayıları | |
| Google Scholar | 22 |
| Web of Science | 13 |
| Dergi Adı | Journal of Clinical Anesthesia |
| Yayıncı | Elsevier Inc. |
| Açık Erişim | Hayır |
| ISSN | 0952-8180 |
| E-ISSN | 1873-4529 |
| CiteScore | 7,4 |
| SJR | 1,082 |
| SNIP | 1,501 |