Duplex Doppler Sonographic Assessment of the Superior Mesenteric Artery in Patients With Mesenteric Panniculitis       
Yazarlar (7)
Berat Acu
Eskişehir Osmangazi Üniversitesi, Türkiye
Mehmet Emrah Güven
Tokat Gaziosmanpaşa Üniversitesi, Türkiye
Mehmet Ali Kaptan
Eskişehir Osmangazi Üniversitesi, Türkiye
Çiğdem Öztunali
Gazi University, Faculty Of Medicine, Türkiye
Prof. Dr. Erkan GÖKÇE Tokat Gaziosmanpaşa Üniversitesi, Türkiye
Doç. Dr. Murat BEYHAN Tokat Gaziosmanpaşa Üniversitesi, Türkiye
Taylan Kara
Mersin Üniversitesi, Türkiye
Makale Türü Özgün Makale
Makale Alt Türü SSCI, AHCI, SCI, SCI-Exp dergilerinde yayınlanan tam makale
Dergi Adı Journal of Ultrasound in Medicine
Dergi ISSN 0278-4297 Wos Dergi Scopus Dergi
Dergi Tarandığı Indeksler SCI-Expanded
Dergi Grubu Q4
Makale Dili İngilizce
Basım Tarihi 01-2018
Cilt No 37
Sayı 1
Sayfalar 165 / 172
DOI Numarası 10.1002/jum.14314
Makale Linki http://doi.wiley.com/10.1002/jum.14314
Özet
Objectives-We aimed to determine how the hemodynamic parameters of the superior mesenteric artery are affected in mesenteric panniculitis. Methods-Twenty-one patients with a diagnosis of mesenteric panniculitis on computed tomography were evaluated with duplex Doppler sonography. The control group consisted 20 asymptomatic volunteers. The peak systolic velocity, enddiastolic velocity (EDV), resistive index (RI), pulsatility index (PI), blood flow volume, and body mass index were measured in the group of patients with mesenteric panniculitis, and the findings were compared with those of the control group. Results-The mean blood flow volume and EDV were significantly higher in the patient group: The mean superior mesenteric artery blood flow volume6SD was 917.86±228.97mL/min in the patient group versus 389.73±92.72mL/min in the control group (P<.001). The mean EDV was 31.56±.44m/s in the patient group versus 19.2764.19m/s in the control group (P<.001). The mean RI and PI were significantly lower in the patient group: The mean RI was 0.8160.04 in the patient group versus 0.85±0.03 in the control group (P5.001). The mean PI was 2.69±0.68 in the patient group versus 3.81±1.13 in the control group (P=.001). the mean superior mesenteric artery diameter was 7.3060.67mm in the patient group versus and 6.4660.66mm in the control group (P<.001). The mean BMI was 27.95±3.80 kg/m2 in the patient group versus 23.16±3.47 kg/m2 in the control group (P<.001). Conclusions-In patients with mesenteric panniculitis, the Doppler spectrum of the superior mesenteric artery shows detectable changes, which are characterized by decreased vascular resistance and increased blood flow.
Anahtar Kelimeler
Doppler (abdominal) | Duplex doppler sonography | Mesenteric panniculitis | Superior mesenteric artery